Demilec Vapor Barrier Installation: The Burbank Owner’s Guide
Demilec vapor barrier installation in Burbank typically runs $1,800-$3,400 for a standard crawl space or attic application, and we stock the full Demilec-compatible membrane range for same-day starts. Most Burbank homeowners discover the problem after a rainy winter or when their spring energy bill jumps 20% without explanation - the barrier has torn at a penetration, delaminated at a seam, or the original installer never sealed the edges to the foundation wall. We carry 6-mil, 10-mil, and 15-mil reinforced polyethylene on every truck, plus seam tape and mastic for the detail work that actually holds.
Which Demilec Models This Applies To
Demilec doesn’t sell a standalone “vapor barrier” SKU under its own label - the brand is best known in Burbank for its Heatlok and Sealection spray foam lines, where the vapor barrier function is either integrated into the foam assembly or requires a supplemental membrane. If your home was insulated with Demilec open-cell foam in the rafters, you likely need a Class II vapor retarder (kraft-faced batts, poly sheeting, or a vapor-retarder paint) on the warm side to meet California Title 24. If it’s closed-cell Demilec, the foam itself is the barrier at 2 inches or greater, but we still see failures where the installer missed the rim joist or didn’t run the foam to the sill plate.
Here’s how to tell what you’ve got: check your insulation paperwork for “Heatlok HFO,” “Heatlok XT,” “Sealection 500,” or “Demilec APX.” The label should also list the installed thickness. Under 2 inches of closed-cell, or any thickness of open-cell, and you’re missing a proper vapor barrier for Burbank’s mixed-humidity climate. We also stock Reflectix as an alternative radiant barrier where attic floor conditions make polyethylene impractical. Topside Attic Insulation Burbank is an independent service provider, not affiliated with Demilec.
Signs Your Demilec Vapor Barrier Installation Is Failing

- Musty smell that worsens after rain. This means moisture is migrating through a compromised barrier and condensing on cooler surfaces. In Burbank’s Magnolia Park neighborhood, we see this often in 1950s-1970s homes where the original builder used 3-mil poly that shredded against the crawl space gravel.
- Insulation sagging or discolored near the eaves. Water vapor has bypassed the barrier, wet the fiberglass, and the batts have lost their loft. The R-value drops by roughly half when fiberglass is compressed or damp.
- Visible condensation on ductwork in summer. Your air handler is sweating because humid outside air is reaching the cold supply ducts through gaps in the barrier. This is common in Burbank’s late-summer monsoon pattern when relative humidity spikes above 60%.
- Mold spotting on the foundation wall or sill plate. The barrier either wasn’t sealed to the wall or the sealant has aged out. Demilec-compatible installations should use a butyl-based mastic at all terminations, not just staples.
- Energy bills climbing with no rate change. A failed vapor barrier lets moisture into the insulation cavity, and wet insulation conducts heat faster than dry. We’ve measured attic floor assemblies in Burbank where effective R-value dropped from R-38 to R-19 because of this.
Before
AfterReplacement Cost & What’s Included
| Component | Typical Range (Burbank) |
|---|---|
| Crawl space vapor barrier (6-mil, up to 1,000 sq ft) | $1,800 - $2,600 |
| Crawl space vapor barrier (10-mil reinforced, up to 1,000 sq ft) | $2,400 - $3,200 |
| Attic vapor retarder with air sealing | $2,200 - $3,400 |
| Seam taping and mastic detail work | Included in above |
| Foundation wall sealing and piers | Included in above |
What moves the number: square footage, accessibility (crawl height under 18 inches adds time), condition of existing insulation that may need removal first, and whether we find active rodent damage that requires cleaning before the new barrier goes down. Every job starts with a written price - no work begins without it - and closes with a Documented Photo Record showing the completed membrane layout and sealed edges. Our 365-Day Done Right Promise covers the installation and materials.
DIY or Call Us?

You can safely check a few things yourself. Look for the Demilec product label in your attic or crawl space. Measure the membrane thickness with a caliper if you have one - 3-mil was common in older Burbank builds and is now below code for crawl spaces. Check for standing water, which means drainage issues that any barrier will eventually fail to.
Where DIY goes wrong: vapor barrier installation looks like laying down a tarp, but the performance lives in the details. Seams must overlap 12 inches and be taped with pressure-sensitive acrylic, not duct tape. The barrier must run 6 inches up the foundation wall and be mechanically fastened with a termination bar, not just stapled. Miss any of this and you’ve spent a weekend for a barrier that leaks at every joint. The R-value is what the label says. The performance is what the blower-door test says. We care about the second number. Call (213) 816-1699 and we’ll give you a written price before anyone lifts a tool - plus a Free Second Opinion if you’ve already got another estimate.
FAQs
A properly installed 10-mil reinforced polyethylene barrier should last 15-20 years in Burbank’s climate, though the 6-mil standard grade often shows seam failure at 8-12 years due to our thermal cycling and occasional rodent activity. Call (213) 816-1699 for an exact quote on replacement - estimates are free.
Patching works for isolated punctures smaller than a softball using compatible polyethylene tape, but widespread delamination, seam failure, or brittle 3-mil poly means full replacement is the only fix that holds. We document the damage with photos and give you a written scope before any work starts.
Most residential crawl spaces in Burbank take one day for a two-person crew; attics with complex penetrations may run into a second day. We arrive with the material on the truck and leave you with a Documented Photo Record and, where applicable, before-and-after blower-door numbers.
Yes - we carry 6-mil, 10-mil, and 15-mil reinforced polyethylene, plus acrylic seam tape, butyl mastic, and termination bars on every truck. For Demilec foam assemblies that need a supplemental Class II retarder, we also stock kraft-faced batts and vapor-retarder primer. Same-day starts are available most days.
Written by Wes Okafor, Owner & Lead Insulation Technician, Topside Attic Insulation Burbank at Topside Attic Insulation Burbank, serving Burbank and nearby areas.